Honeywell 800-08091V3 manual User System Setup contd

Models: 800-08091V3

1 48
Download 48 pages 53.01 Kb
Page 31
Image 31
User System Setup (cont'd)

User System Setup (cont'd)

LED Test

ICON

ACTION

NOTES

 

 

 

 

1. Press the LED Test icon; "Testing.." is displayed

At the conclusion of the test, a pop-up "Confirmation Window" displays:

 

 

 

 

 

 

 

 

while the 3 LEDs light sequentially, top to

"Did you see chasing LED pattern?"

 

 

 

 

 

 

 

 

bottom (red, green, yellow), 5 times.

If you press Yes, "Passed" is displayed in the test status column.

 

 

 

 

If you press No, "Failed" is displayed in the test status column.

 

 

 

 

 

Calibration

Test

 

ICON

 

ACTION

NOTES

 

 

 

 

1. Select the Calibration icon and using a stylus,

A pop-up message displays:

 

 

 

 

 

 

follow the

screen directions by pressing a

Touch screen calibration

 

 

 

 

 

 

 

series of crosshairs (+) and boxes () on the

Touch crosshair to calibrate

 

 

 

 

If the Calibration test was successful, a confirmation screen appears stating:

 

 

 

 

screen until done.

 

 

 

 

Congratulations Calibration Success”

 

 

 

 

2. If the test was successful, press OK; the screen

 

 

 

 

If the test was unsuccessful, an error message appears stating:

 

 

 

 

returns to the Keypad Test screen.

“Calibration failed, do you want to retry?” Retry, Ignore or Exit.

Z-Wave Test

NOTE: This procedure is for Z-Wave test purposes only.

Role shifting is the process of shifting primary and secondary controllers. The secondary controller becomes the primary controller with the ability to enroll Z-Wave devices. This is useful when the primary controller is in a fixed location and the Z- wave device is not easily accessible (but within Z-wave range). To perform the role shifting Z-Wave Test, do the following:

 

ICON

 

ACTION

NOTES

 

 

1.

Press the Advanced Setup icon.

Select from two main categories of tests:

 

 

 

 

 

 

2.

Enter your Authorized Code.

Z-Wave Role Shifting: Primary to

 

 

 

 

 

 

 

3.

Press the Keypad Test icon.

Secondary and Secondary to Primary.

 

 

 

 

 

 

 

4.

With the status of the controller in the “P” (Primary) state, press the Z-

Z-Wave Basic Command: Set On or

 

 

 

 

 

 

 

 

 

 

 

 

 

Wave Primary Controller Shift to Secondary icon.

Off.

 

 

 

 

 

 

 

 

A pop-up window is displayed with the following warning: “Warning!! This Z-

 

 

 

 

 

 

 

 

 

Wave controller shift function is for evaluation only now. This primary controller is

Note: The status of the controller can only

 

 

 

 

 

 

 

 

shifting to the secondary. Please wait until the process completes.

be changed from Primary to Secondary

 

 

 

 

 

 

 

 

5.

To shift the primary controller role to a handheld controller, follow the

 

 

 

 

controller when no devices are enrolled.

 

 

 

 

 

 

 

 

 

handheld controller manufacturer’s instructions.

Use the delete device or reset controller

 

 

 

 

 

 

 

 

 

The pop-up message disappears and controllers have shifted successfully.

function to remove enrolled devices.

 

 

 

 

 

 

 

 

 

Z-Wave devices can now be enrolled from this controller.

 

 

 

 

 

 

 

 

 

Note: The Z-Wave Primary Controller Shift to Secondary icon is inactive

 

 

 

 

 

 

 

 

 

when the Tuxedo Touch becomes the secondary controller.

 

 

 

 

 

 

 

 

 

The Shift is completed when the warning window disappears.

 

 

 

 

 

 

 

 

 

6. Shift the Tuxedo Touch back to the primary controller after enrolling Z-

 

 

 

 

 

 

 

 

 

wave devices. First, initiate the role shift on the handheld controller from

 

 

 

 

 

 

 

 

 

primary to secondary referring to manufacturer’s instructions. Then, press

 

 

 

 

 

 

 

 

 

the Z-Wave Secondary Controller Shift to Primary icon on the keypad.

 

31

Page 31
Image 31
Honeywell 800-08091V3 manual User System Setup contd