Security (cont'd)
To disarm Multi-Partitions do the following:
ICON | ACTION | NOTES |
| 1. From the “Home” screen, press the Security | The keypad displays |
| icon. |
|
2.Press the Arm
3.Press the Disarm icon.
4. Enter your
5. Highlight the partition(s) to disarm and press OK, or press ALL to disarm all partitions.
How to Check the Status of Other Partitions
This system supports between one and eight Partitions (depending on the system.) Partitioning enables a single physical alarm system to control up to eight areas of protection (partitions) depending on the system you have purchased. Each
Note: A letter “H” following the partition name or number indicates that this is the default partition for the keypad.
For example, if your physical site is a
If a user is so authorized, a keypad or other keypad in one partition can be used to perform system functions in another partition. (Note that only those partitions authorized and programmed by the installer can be accessed in this manner.)
To check the status of other partitions perform the following:
ICON | ACTION | NOTES | |||
1. | Press the SECURITY icon. | This screen displays the available partitions and their current status. | |||
|
| 2. | Press the "Current Partition" icon (lower | The current partition is shown at the top of the display (P1). To change this | |
|
|
| edge of the screen; in this case it displays P1 assignment, select the appropriate icon (e.g., press P2 to switch control to | ||
|
|
| |||
|
|
| H unless changed by installer). | Partition 2). | |
3. | Enter the code authorized to access other | Note: After leaving this screen when using a residential panel, the selected | |||
partition in the keypad automatically reverts back to the keypad’s home | |||||
|
|
| partition(s). | ||
|
|
| partition after two minutes. When using commercial panels, you must select | ||
|
| If the code is accepted, the system displays the | the keypad’s home partition to return to it. | ||
|
| partitions that user has access to. | Note: A code may have access to some or all of the available partitions. | ||
|
|
|
|
Fire and Carbon Monoxide Alarm Operation
Your fire alarm system and carbon monoxide detector (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke, heat, carbon monoxide detectors automatically send signals to your Control/Communicator, triggering a loud interrupted sound from the keypad. An interrupted sound is also produced by optional exterior sounders. EVACUATE ALL OCCUPANTS FROM THE PREMISES IMMEDIATELY. Notify your Central Station/Security Company immediately and wait for further instructions.