Honeywell 800-08091V3 manual Scene Setup, Automation contd, Action, Scene Icons, Scene Rules

Models: 800-08091V3

1 48
Download 48 pages 53.01 Kb
Page 37
Image 37
Scene Setup

Automation (cont'd)

Scene Setup

The “Scene” feature is used to control the function of a single device, or multiple devices based on pre-set Conditions, Triggers, and Actions. When the trigger/condition occurs, the action is executed. Define a Scene as follows:

ICON

ACTION

NOTES

1. At the Tuxedo Touch Keypad:

Enter the new device name by entering it on the data entry keyboard.

a)

Press the Automation and Scene Setup icons

Use the Shift icon for capital letters.

b)

to display the “Scene Management” screen.

Use the BS (Backspace) icon to make corrections.

Press the Add icon to set up a Scene.

The @#$ icon is not available for use at this time.

c) Press the Name box, enter a Scene Name and

 

 

press OK.

 

d) Select a “Condition,” “Trigger,” and “Action”

After each selection press Save!! !

 

that you want to occur for this Scene. See

 

example below.

 

Scene Icons

 

 

Add

Edit

Delete

After each selection is complete, press Save to keep the settings, press Delete to cancel, or Edit to change your selections.

Scene Rules

Triggers and Conditions include: Time setting, Security mode, Thermostat setting, Door status and Zones.

Actions include: Security mode, Lights on/off, Thermostat setting, and Door Lock status.

Each Trigger event can have up to 3 Actions.

A Trigger event and Condition cannot be the same (i.e., if setting a Trigger event for Security, you cannot set a Security Condition).

A total of 10 Scenes can be created.

On commercial panels the programming option for “Global Keypad” must be set to “0” for some Scenes to work properly.

Note: Determine if you need a Condition. The Condition is a ‘pre-condition’ set to occur prior to a trigger event. See example below.

Example: Turn the lights on, when the system is disarmed, only at night.

(Condition)

… “only at Night”

...Set the TIME condition (enter the Start Time and End Time).

(Trigger)

“when the “system is Disarmed” …Set the Trigger to SECURITY: System Disarm

(Action)

Turn the “lights ON” …

… Set the Action to LIGHT: ON

37

Page 37
Image 37