6. ELECTRICAL CONNECTION

ENGLISH

Fig. 5

6. ELECTRICAL CONNECTION

WARNING

THIS APPLIANCE MUST BE EARTHED

This icemaker requires an earth that meets the na- tional and local electrical code requirements. To prevent possible severe electrical shock to individu- als or extensive damage to equipment, install a proper earth wire to the icemaker. Turn off the power supply before any maintenance, repairs or cleaning is undertaken.

This icemaker must have a separate power supply or receptacle of proper capacity. See the Nameplate. It is recommended that this icemaker be the only electrical device on its power supply circuit.

Stacked icemakers should each have a separate receptacle, but they must all be connected in parallel to the same single phase supply or circuit with sufficient ampacity.

The opening for the power supply connection is

22.2mm. diameter to fit a conduit.

If a power cord is used to provide electricity to the icemaker in place of the permanent (conduit) connection, a gland should be installed at the 22.2 mm. power supply connection. This gland should be of the correct size for the power supply cord being installed. The size of the conductors of this power supply cord should be suitable for the electrical consumption of this icemaker.

As the colours of the wires in the terminal box of this appliance may not correspond with field supplied wiring or with the markings identifying the terminals in your power supply receptacle, proceed as follows:

The wire which is coloured Green-and-Yellow must be connected to the terminal in the receptacle which is marked

with the letter E or by the symbol THIS APPLIANCE MUST BE EARTHED or coloured Green or Green-and-Yellow. The wire which is coloured Blue must be connected to the terminal which is marked with the letter “N” or coloured Black. The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red.

Usually an electrical permit and services of a licensed electrician are required.

For the electrical connection of the URC-12F-E remote condenser unit to the fan motor junction of the KM- 1300SRH-E, an IPX4 rated conduit is recommended. If a power supply cord is used, the cord itself should be certified for outdoor use and a gland rated IPX4 should be used where the cord enters the model URC-12F-E remote condenser.

Usually an electrical permit and services of a licensed electrician are required.

7.INSTALLATION OF REMOTE CONDENSER UNIT (Remote Air-Cooled Model Only)

[a] UNPACKING

1)Unpack and remove shipping carton, tape(s) and packing.

2)Check that the refrigerant lines do not rub or touch lines or other surfaces, and that the fan blade turns freely.

[b] LOCATION

The condenser unit is intended for outdoor use and must be positioned in a permanent, well ventilated site under the following guidelines:

Select a firm and flat site.

Should not be exposed to harsh or adverse weather conditions.

5