Hoshizaki KM-260BWH, KM-260BAH b Harvest Timer S1 dip switch, c Pump-OutTimer S1 dip switch

Models: KM-201BWH KM-260BWH KM-201BAH KM-260BAH

1 81
Download 81 pages 49.56 Kb
Page 22
Image 22
Fig. 1

S1 Dip Switch

S2 Dip Switch

Freeze Timer (9 & 10)

Water Saver Timer (7 & 8)

Pump-Out Frequency Control (5 & 6)

Pump-Out Timer (3 & 4)

Harvest Timer (1 & 2)

Fig. 2 Anti-Slush Control (5 & 6)

b) Harvest Timer (S1 dip switch 1 & 2) Refill Counter (3 & 4)

c) Pump-Out Timer (S1 dip switch 3 & 4) Float Switch Selector (2)

Pump-Out/Drain Selector (1)

*Functions of S2 dip switch nos. 2 through 6 depend on program version.

Fig. 1

Fig. 2

b) Harvest Timer (S1 dip switch 1 & 2)

Used for adjustment of the harvest timer. The harvest timer starts counting when the thermistor reads a certain temperature at the evaporator outlet.

Dip Switch Setting

Time

No. 1

No. 2

(seconds)

OFF

OFF

60

ON

OFF

90

OFF

ON

120

ON

ON

180

c) Pump-Out Timer (S1 dip switch 3 & 4)

Once every ten freeze cycles, the drain valve opens to drain the water tank for the time determined by the pump-out timer. These switches also determine the time to delay completion of a defrost cycle, i.e. the minimum defrost time.

Do not change this setting, or the unit will not operate properly or produce high quality ice.

Dip Switch Setting

Time (seconds)

No. 3

No. 4

T1

T2

OFF

OFF

10

120

ON

OFF

10

180

OFF

ON

20

120

ON

ON

20

180

T1: Time to drain the water tank

T2: Harvest timer at pump-out