PROBLEM | POSSIBLE CAUSE |
| REMEDY | ||
|
|
|
|
|
|
[4] Water | a) Inlet Water Valve | 1. | Diaphragm does not | 1. | Check for water leaks |
continues to |
|
| close. |
| with icemaker off. |
be supplied in |
|
|
|
| Replace if necessary. |
freeze cycle. | b) Control Board | 1. | Defective. | 1. | See “II. 3. [d] CONTROL |
|
|
|
|
| BOARD CHECK |
|
|
|
|
| PROCEDURE”. |
[5] No water | a) Water Supply Line | 1. | Water pressure too low | 1. | Check and get |
comes from |
|
| and water level in water |
| recommended pressure. |
Spray Tubes. |
|
| tank too low. |
|
|
Water Pump | b) Inlet Water Valve | 1. | Dirty mesh filter or | 1. | Clean. |
will not start, or |
|
| orifice and water level in |
|
|
freeze cycle |
|
| water tank too low. |
|
|
time is too | c) Water System | 1. | Water leaks. | 1. | Check connections for |
short. |
|
|
|
| water leaks, and replace. |
|
| 2. | Clogged. | 2. | Clean. |
| d) Pump Motor | 1. | Motor winding opened. | 1. | Replace. |
|
| 2. | Bearing worn out. | 2. | Replace. |
|
| 3. | Wiring to pump motor. | 3. | Check for loose |
|
|
|
|
| connection or open, and |
|
|
|
|
| replace. |
|
| 4. | Defective capacitor. | 4. | Replace. |
|
| 5. | Defective or bound | 5. | Replace and clean. |
|
|
| impeller. |
|
|
| e) Control Board | 1. | Defective. | 1. | See “II. 3. [d] CONTROL |
|
|
|
|
| BOARD CHECK |
|
|
|
|
| PROCEDURE”. |
[6] Fan Motor will | a) Fan Motor | 1. | Motor winding opened. | 1. | Replace. |
not start, or is |
| 2. | Bearing worn out. | 2. | Replace. |
not operating. |
| 3. | Wiring to fan motor. | 3. | Check for loose |
|
|
|
|
| connection or open, and |
|
|
|
|
| replace. |
|
| 4. | Fan blade bound | 4. | Check and replace. |
|
|
| (locked fan motor). |
|
|
| b) Control Board | 1. | Defective. | 1. | See “II. 3. [d] CONTROL |
|
|
|
|
| BOARD CHECK |
|
|
|
|
| PROCEDURE”. |
[7] All | a) Refrigerant | 1. | Undercharged. | 1. | Check for leaks and |
components |
|
|
|
| recharge. |
run but no ice |
| 2. | Air or moisture trapped. | 2. | Replace drier, and |
is produced. |
|
|
|
| recharge. |
| b) Compressor | 1. | Defective. | 1. | Replace. |
| c) Hot Gas Solenoid | 1. | Continues to open in | 1. | Check and replace. |
| Valve |
| freeze cycle. |
|
|
41