d) Pump-Out Frequency Control (S1 dip switch 5 & 6)
The water tank drains at the frequency set by the
The
Dip Switch Setting | Frequency | ||
No. 5 | No. 6 | ||
| |||
OFF | OFF | every cycle | |
ON | OFF | every 2 cycles | |
OFF | ON | every 5 cycles | |
ON | ON | every 10 cycles |
e) Harvest Pump Timer (S1 dip switch 7 & 8)
The harvest pump timer allows the water valve to close and the pump motor to circulate water in the tank during the final part of harvest. The water valve is open during harvest for a maximum of 6 minutes or the length of harvest minus 0, 10, 30, or 50 seconds (determined by the harvest pump timer setting), whichever is shorter. When the water valve closes, the pump motor energizes and runs for the time determined by the harvest pump timer setting.
The harvest pump timer is
Dip Switch Setting | Time | |
No. 7 | No. 8 | (seconds) |
OFF | OFF | 0 |
ON | OFF | 10 |
OFF | ON | 30 |
ON | ON | 50 |
f) Freeze Timer (S1 dip switch 9 & 10)
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible
18