Hoshizaki KM-201BAH, KM-260BAH, KM-260BWH, KM-201BWH service manual Water Valve

Models: KM-201BWH KM-260BWH KM-201BAH KM-260BAH

1 81
Download 81 pages 49.56 Kb
Page 65
Image 65
13. WATER VALVE

13. WATER VALVE

1)Unplug the icemaker or disconnect the power source.

2)Close the water supply tap.

3)Remove the top panel, rear panel and side panel (R).

4)Disconnect the tab terminals.

5)Pinch and lower the hose clamp.

6)Disconnect the rubber hose from the water valve. Put a towel under the water valve to receive water coming out.

7)Turn the inlet nut in the arrow direction to remove it from the water valve. Do not lose the gasket inside.

8)Remove the two mounting screws.

9)Install the new valve in the reverse order of the removal procedure.

10)Tighten the inlet nut to a torque of 7.85 N•m (±5%) to prevent water leaks.

11)Open the water supply tap.

12)Plug in the icemaker or connect the power source.

13)Check for leaks.

14)Refit the panels in their correct positions.

Rubber Hose

Hose Clamp Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Mounting Screw

Tab Terminal

Inlet Nut

Fig. 10

60

Page 65
Image 65
Hoshizaki KM-201BAH, KM-260BAH, KM-260BWH, KM-201BWH service manual Water Valve