Cut ties to make Bulb |
|
removable | Bulb |
Bulb Insulation Hose
Remove Expansion | Expansion Valve |
Valve Cover first |
|
Fig. 5
7.
CAUTION
1.Always install a new drier every time the sealed refrigeration system is opened.
2.Do not replace the drier until after all other repair or replacement has been made. Install the new drier with the arrow on the drier in the direction of the refrigerant flow.
3.When brazing, protect the drier by using a wet cloth to prevent the drier from overheating. Do not allow the drier to exceed 250°F (121°C).
1)Unplug the icemaker or disconnect the power source.
2)Remove the panels.
3)Recover the refrigerant and store it in an approved container.
4)Disconnect the condenser inlet and outlet piping.
5)Remove the fan motor bracket from the condenser.
6)Remove the screws securing the condenser assembly, then remove the assembly.
53