[d]
APPROXIMATE ICE | AMBIENT TEMP. |
|
| WATER TEMP. (ºF/ºC) |
|
| |||||
PRODUCTION PER 24 HR. | (ºF/ºC) |
|
|
|
|
|
|
| |||
| 50/10 |
| 70/21 |
|
| 90/32 | |||||
|
|
|
| 70/21 | 268 | 122 | 259 | 117 |
| 242 | 110 |
|
|
|
| 80/27 | 261 | 118 | 247 | 112 |
| 228 | 103 |
|
|
|
| 90/32 | 259 | 117 | 237 | 108 |
| 218 | 99 |
lbs./day |
| kg./day | 100/38 | 254 | 115 | 233 | 106 |
| 201 | 91 | |
|
|
|
|
|
|
|
|
|
|
| |
APPROXIMATE ELECTRIC | 70/21 |
| 620 |
| 623 |
|
| 624 | |||
CONSUMPTION | 80/27 |
| 622 |
| 627 |
|
| 626 | |||
|
|
|
| 90/32 |
| 623 |
| 630 |
|
| 630 |
watts |
|
|
| 100/38 |
| 622 |
| 630 |
|
| 630 |
APPROXIMATE WATER | 70/21 | 77 | 0.29 | 73 | 0.27 |
| 65 | 0.25 | |||
CONSUMPTION PER 24 HR. | 80/27 | 74 | 0.28 | 67 | 0.25 |
| 58 | 0.22 | |||
|
|
|
| 90/32 | 73 | 0.27 | 62 | 0.24 |
| 54 | 0.20 |
gal./day |
| m3/day | 100/38 | 65 | 0.25 | 60 | 0.23 |
| 46 | 0.17 | |
FREEZING CYCLE TIME | 70/21 |
| 21 |
| 22 |
|
| 24 | |||
|
|
|
| 80/27 |
| 22 |
| 23 |
|
| 25 |
|
|
|
| 90/32 |
| 22 |
| 24 |
|
| 26 |
min. |
|
|
| 100/38 |
| 22 |
| 24 |
|
| 28 |
HARVEST CYCLE TIME | 70/21 |
| 2.6 |
| 2.5 |
|
| 2.0 | |||
|
|
|
| 80/27 |
| 2.5 |
| 2.3 |
|
| 2.0 |
|
|
|
| 90/32 |
| 2.5 |
| 2.1 |
|
| 2.0 |
min. |
|
|
| 100/38 |
| 2.3 |
| 2.1 |
|
| 2.0 |
HEAD PRESSURE | 70/21 | 285 | 20.0 | 285 | 20.0 |
| 285 | 20.0 | |||
|
|
|
| 80/27 | 285 | 20.0 | 285 | 20.0 |
| 285 | 20.0 |
|
|
|
| 90/32 | 285 | 20.0 | 285 | 20.0 |
| 285 | 20.0 |
PSIG | kg/cm2G | 100/38 | 285 | 20.0 | 285 | 20.0 |
| 285 | 20.0 | ||
SUCTION PRESSURE | 70/21 | 46 | 3.2 | 47 | 3.3 |
| 51 | 3.6 | |||
|
|
|
| 80/27 | 46 | 3.3 | 47 | 3.3 |
| 53 | 3.7 |
|
|
|
| 90/32 | 47 | 3.3 | 48 | 3.4 |
| 53 | 3.7 |
PSIG | kg/cm2G | 100/38 | 49 | 3.4 | 49 | 3.5 |
| 58 | 4.1 |
TOTAL HEAT OF REJECTION FROM CONDENSER | 3,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
TOTAL HEAT OF REJECTION FROM COMPRESSOR | 800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)] |
WATER FLOW FOR CONDENSOR | 䇭䇭 30 gal./h [AT 100ºF(38 ) / WT 90ºF(32 )] |
PRESSURE DROP OF COOLING WATER LINE | 㫃㪼㫊㫊㩷㫋㪿㪸㫅㩷㪈㪇㩷㪧㪪㪠㪞 |
Note: Pressure data is recorded at 5 minutes into freezing cycle.
We reserve the right to make changes in specifications and design without prior notice.
36