PROBLEM | POSSIBLE CAUSE |
| REMEDY | ||
|
|
|
|
|
|
[1] (Continued) | l) Control Board | 1. | Defective. | 1. | See “II. 3. [d] CONTROL |
|
|
|
|
| BOARD CHECK |
|
|
|
|
| PROCEDURE”. |
[2] Water | a) Float Switch | 1. | Connector | 1. | Reconnect. |
continues to |
|
| disconnected. |
|
|
be supplied, |
| 2. | Leads opened or | 2. | Check and replace. |
and the |
|
| defective switch. |
|
|
icemaker will |
| 3. | Float does not move | 3. | Clean or replace. |
not start. |
|
| freely. |
|
|
| b) Control Board | 1. | Defective. | 1. | Replace. |
[3] Compressor | a) Control Switch | 1. | WASH position. | 1. | Move to ICE position. |
will not start or |
| 2. | Bad contacts. | 2. Check and replace. | |
operates | b) High Pressure | 1. | Dirty air filter or | 1. | Clean. |
intermittently. | Control |
| condenser. |
|
|
|
| 2. | Ambient temperature | 2. | Reduce ambient |
|
|
| too warm. |
| temperature. |
|
| 3. | Refrigerant | 3. | Recharge. |
|
|
| overcharged. |
|
|
|
| 4. | Fan not operating. | 4. | See chart 2 - [6]. |
|
| 5. Condenser water | 5. | Check and get | |
|
|
| temperature too warm |
| recommended |
|
|
|
| temperature. | |
|
| 6. | Refrigerant line or | 6. | Clean and replace drier. |
|
|
| components plugged. |
|
|
| c) Overload | 1. | Bad contacts. | 1. | Check for continuity and |
| Protector |
|
|
| replace. |
|
| 2. | Voltage too low. | 2. | Increase voltage. |
|
| 3. | Refrigerant overcharged | 3. | Recharge. |
|
|
| or undercharged. |
|
|
| d) Starter | 1. | Bad contacts. | 1. | Check and replace. |
|
| 2. | Coil winding opened. | 2. | Replace. |
| e) Start Capacitor | 1. Defective. | 1. | Replace. | |
| f) Power Relay | 1. | Bad contacts. | 1. | Check for continuity and |
|
|
|
|
| replace. |
|
| 2. | Coil winding opened. | 2. | Replace. |
| g) Compressor | 1. | Wiring to compressor. | 1. | Check for loose |
|
|
|
|
| connection or open, and |
|
|
|
|
| replace. |
|
| 2. | Defective. | 2. | Replace. |
|
| 3. | Protector tripped. | 3. | Reduce temperature and |
|
|
|
|
| verify cause. |
| h) Control Board | 1. | Defective. | 1. | See “II. 3. [d] CONTROL |
|
|
|
|
| BOARD CHECK |
|
|
|
|
| PROCEDURE”. |
| i) Condenser, Air | 1. | Clogged with dirt and | 1. | Clean and unclog. |
| Filter |
| dust. |
|
|
| j) Water regulator | 1. | Set too high. | 1. | Adjust lower. |
| 2. | Clogged or defective. | 2. Clean or replace. | ||
| model) |
|
|
|
|