Hoshizaki KM-260BAH, KM-201BAH, KM-260BWH, KM-201BWH Water Tank, fCONTROL BOARD TRANSFORMER

Models: KM-201BWH KM-260BWH KM-201BAH KM-260BAH

1 81
Download 81 pages 49.56 Kb
Page 72
Image 72
[f]CONTROL BOARD TRANSFORMER

3)To prevent miswiring, check the terminal numbers and lead wire colors with the wiring label.

[f]CONTROL BOARD TRANSFORMER

1)Disconnect the connectors and closed end connectors connecting the control board. (The tie securing the harness may be removed. But be careful not to break the lead wires.)

2)Remove the mounting screw and lift off the transformer from the fit at the bottom.

3)Install the new transformer in the reverse order of the removal procedure.

19. WATER TANK

1)Drain out the water tank by leaving the control switch in the “SERVICE” position and the service switch in the “DRAIN” position for several tens of seconds.

2)Unplug the icemaker or disconnect the power source. Remove all ice from the storage bin.

3)Disconnect the overflow pipe.

4)Remove the two thumbscrews. Pull the water tank slightly toward you and push it down. Be careful to avoid breakage when handling the parts. See Fig. 17.

5)Refit the water tank in the reverse order of the removal procedure.

6)Plug in the icemaker or connect the power source.

Water Tank

Overflow Pipe

Thumbscrew

Fig. 17

67

Page 72
Image 72
Hoshizaki KM-260BAH, KM-201BAH, KM-260BWH, KM-201BWH service manual Water Tank, fCONTROL BOARD TRANSFORMER