5)Install the new fan motor in the reverse order of the removal procedure.
6)Refit the panels in their correct positions.
7)Plug in the icemaker or connect the power source.
Screw
Fan Motor
Fan Motor Bracket
Fig. 6
10.WATER REGULATING VALVE
1.Always install a new drier every time the sealed refrigeration system is opened.
2.Do not replace the drier until after all other repair or replacement has been made. Install the new drier with the arrow on the drier in the direction of the refrigerant flow.
3.When brazing, protect the drier by using a wet cloth to prevent the drier from overheating. Do not allow the drier to exceed 250°F (121°C).
1)Unplug the icemaker or disconnect the power source.
2)Remove the panels.
3)Close the condenser water supply line
56