18. CONTROL BOX
1)Unplug the icemaker or disconnect the power source.
2)Remove the louver.
3)Remove the two mounting screws, and pull the control box toward you.
4)Refit the removed parts in the reverse order of the removal procedure.
Note: After replacing the components inside the control box, connect and tie the wires properly in their correct position. Especially make sure that the harness does not press the push buttons on the control board.
Screw
Pull toward you
Control Box
Control Board
Power Relay
Transformer | Power Switch |
|
Fuse
Fuse Holder
Fig. 16
65