6. OTHER
PROBLEM | POSSIBLE CAUSE |
| REMEDY | ||
|
|
|
|
|
|
[1] Icemaker will | a) Bin Control Switch | 1. | Completely | 1. | Place in position. |
not stop when |
|
| disconnected and |
|
|
bin is filled with |
|
| dropped inside bin. |
|
|
ice. |
| 2. | Detector broken. | 2. | Replace. |
|
| 3. | Detector out of position. | 3. | Place in position. |
|
| 4. | Defective reed switch. | 4. | Check for continuity and |
|
|
|
|
| replace. |
|
| 5. | Reed switch out of | 5. | Place in position. |
|
|
| position. |
|
|
|
| 6. | Magnet disconnected | 6. | Place in position. |
|
|
| from detector. |
|
|
| b) Control Board | 1. | Defective. | 1. | See “II. 3. [d] CONTROL |
|
|
|
|
| BOARD CHECK |
|
|
|
|
| PROCEDURE”. |
[2] Abnormal | a) Pump Motor | 1. | Bearings worn out. | 1. | Replace. |
noise | b) Fan Motor | 1. | Bearings worn out. | 1. | Replace. |
|
| 2. | Fan blade deformed. | 2. | Replace fan blade. |
|
| 3. | Fan blade does not | 3. | Replace. |
|
|
| move freely. |
|
|
| c) Compressor | 1. | Bearings worn out, or | 1. | Replace. |
|
|
| cylinder valve broken. |
|
|
|
| 2. | Mounting pad out of | 2. | Reinstall. |
|
|
| position or loose |
|
|
|
|
|
|
| |
| d) Refrigerant Lines | 1. | Rub or touch lines or | 1. | Reposition. |
|
|
| other surfaces. |
|
|
[3] Ice in Storage | a) Bin Drain | 1. | Plugged. | 1. | Clean. |
Bin often |
|
|
|
|
|
melts. |
|
|
|
|
|
44