Hoshizaki KM-260BAH, KM-201BAH, KM-260BWH, KM-201BWH service manual No Ice Production

Models: KM-201BWH KM-260BWH KM-201BAH KM-260BAH

1 81
Download 81 pages 49.56 Kb
Page 44
Image 44

2. NO ICE PRODUCTION

PROBLEM

POSSIBLE CAUSE

 

REMEDY

 

 

 

 

 

 

[1] The icemaker

a) Power Supply

1.

OFF position.

1.

Move to ON position.

will not start.

 

2.

Loose connections.

2.

Tighten.

 

 

3.

Bad contacts.

3.

Check for continuity and

 

 

 

 

 

replace.

 

 

4.

Voltage too high.

4.

Check and get

 

 

 

 

 

recommended voltage.

 

 

5.

Unplugged.

5.

Plug in.

 

b) Fuse (inside fused

1.

Blown out.

1.

Check for short circuit and

 

disconnect, if any)

 

 

 

replace.

 

c) Control Switch

1.

OFF or SERVICE

1.

Move to ICE position.

 

 

 

position.

 

 

 

 

2.

Bad contacts.

2.

Check for continuity and

 

 

 

 

 

replace.

 

d) Bin Control Switch

1.

Tripped with bin filled

1.

Remove ice.

 

 

 

with ice.

 

 

 

 

2.

Defective reed switch.

2.

Check for continuity and

 

 

 

 

 

replace.

 

e) High Pressure

1.

Bad contacts.

1.

Check for continuity and

 

Control

 

 

 

replace.

 

f) Transformer

1.

Thermal fuse blown out

1.

Replace.

 

 

 

or coil winding opened.

 

 

 

g) Wiring to Control

1.

Loose connections or

1.

Check for continuity and

 

Board

 

open.

 

replace.

 

h) Thermistor

1.

Leads shorted or open

1.

See “II. 4.

 

 

 

and high temperature

 

THERMISTOR”.

 

 

 

safety operates. If open,

 

 

 

 

 

unit will start but have

 

 

 

 

 

long harvest cycle.

 

 

 

i) Hot Gas Solenoid

1.

Continues to open in

1.

Check for power off in

 

Valve

 

freeze cycle and high

 

freeze cycle and replace.

 

 

 

temperature safety

 

 

 

 

 

operates.

 

 

 

j) Water Supply Line

1.

Water supply off and

1.

Check and get

 

 

 

water supply cycle does

 

recommended pressure.

 

 

 

not finish.

 

Check for water supply.

 

 

2. Condenser water

2. Check and get

 

 

 

pressure too low or off

 

recommended pressure.

 

 

 

and high pressure

 

 

 

 

 

control opens and

 

 

 

 

 

closes frequently

 

 

 

 

 

(water-cooled model).

 

 

 

k) Inlet Water Valve

1.

Mesh filter or orifice

1.

Clean. Replace if

 

 

 

gets clogged and water

 

necessary.

 

 

 

supply cycle does not

 

 

 

 

 

finish.

 

 

 

 

2.

Coil winding opened.

2.

Replace.

 

 

3.

Wiring to water valve.

3.

Check for loose

 

 

 

 

 

connection or open, and

 

 

 

 

 

replace.

39

Page 44
Image 44
Hoshizaki KM-260BAH, KM-201BAH, KM-260BWH, KM-201BWH service manual No Ice Production