Presario 1700 Series

Models: XL260, XL261, XL262, XL264, XL265, XL266, XL274, XL275, XL360, XL361, XL362, XL363, XL364, XL365, XL366, XL367, XL368, XL369, XL370, XL371, XL372, XL373, XL374, XL375, XL376, XL377, and XL378

 

 

Processor Test Error Codes

Error Code

Description

 

Recommended Action

 

 

 

 

 

101-xx

102-xx

103-xx

104-xx

105-xx

106-xx

107-xx

108-xx

109-xx

110-xx

113-xx

114-01

200-xx

202-xx

203-xx

204-xx

211-xx

214-xx

215-xx

CPU test failed

Coprocessor or Weitek Error

DMA page registers test failed

Interrupt controller master test failed

Port 61 error

Keyboard controller self-test failed

CMOS RAM test failed

CMOS interrupt test failed

CMOS clock test failed

Programmable timer load data test failed

Protected mode test failed

Speaker test failed

Memory machine ID test failed

Memory system ROM checksum failed

Write/Read test failed

Address test failed

Random pattern test failed

Noise test failed

Random address test failed

Replace the processor and retest.

1.Run the Configuration and Diagnostics Utilities.

2.Replace the processor board and retest.

The following applies to error codes

103-xx through 114-01:

Replace the system board and retest.

1.Check system configuration.

2.Verify cable connections to speaker.

3.Replace the system board and retest.

The following steps apply to error codes

200-xx and 202-xx:

1.Flash the system ROM and retest.

2.Replace the system board and retest.

The following steps apply to error codes

203-xx through 215-xx:

1.Remove the memory module and retest.

2.Install a new memory module and retest.

Page 55
Image 55
HP 17XL266, 17XL274, 17XL265, 17XL264, 17XL261 manual Processor Test Error Codes, Error Code Description Recommended Action