Windows specific — monitored items definitions section of the configuration file
[sysvar]
filesystemtype: SYSTEM
mountpoint: %%var%%
CriticalThreshold: 95
CriticalActionGE:
CriticalActionLT:
WarnThreshold: 80
WarnActionGE:
WarnActionLT: NONE
[syspart]
filesystemtype: SYSTEM
mountpoint: %%var%%\part
CriticalThreshold: 95
CriticalActionGE:
CriticalActionLT:
WarnThreshold: 80
WarnActionGE:
WarnActionLT: NONE
[syslog]
filesystemtype: SYSTEM
mountpoint: %%var%%\log
CriticalThreshold: 95
CriticalActionGE:
CriticalActionLT:
WarnThreshold: 80
WarnActionGE:
WarnActionLT: NONE
#For the above cases HHM will send
#* the warning and the critical thresholds are crossed upwards
#* the critical threshold is crossed downwards
#If the warning threshold is crossed downwards, nothing happens. NONE is reserved
#for this proposal.
#[hsmfs01]
#filesystemtype: HSMFS
#mountpoint: c:\hsm\fs01
#CriticalThreshold: 95
194 Monitoring and maintaining FSE