Location Codes

The following codes are returned in the Location field of the log record header. These codes are listed according to the Entity that is printed in the Entity field of the log record header when they occur.

Entity: INPRO

The following codes are printed to the Location field of the log record header when the event class is Warning (Class 3), Error (Class 4), Disaster (Class 5), or RsrceLim (Class 6), and the Entity printed in the Entity field is INPRO.

INPRO Location Codes

Location

Meaning

Action

 

 

 

–301

INPRO has encountered a •No

If this condition persists,

 

Abort" return from its Class I/O

NSARPA must be shutdown

 

GET call. If the •No Abort" return

and reinitialized. If shutdown

 

indicates that INPRO's class

and reinitialization do not solve

 

number is no longer valid, or if

the problem, notify your HP field

 

two successive Class I/O GET

office.

 

calls encounter a •No Abort"

 

 

return, the event class is logged

 

 

as Disaster and INPRO is

 

 

aborted. UPLIN will reschedule

 

 

INPRO after performing all

 

 

possible cleanup. A and B

 

 

register information is returned

 

 

in the xx and yy fields of the log

 

 

record header. This is an

 

 

NSARPA internal error.

 

 

 

 

–302

While starting up, INPRO was

If this condition persists,

 

unable to find a valid class

NSARPA must be shutdown

 

number for its use in the DSAM

and reinitialized. If shutdown

 

storage area. After logging this

and reinitialization do not solve

 

message, INPRO will abort.

the problem, this error requires

 

UPLIN will reschedule INPRO

HP notification.

 

after performing all possible

 

 

cleanup. The invalid class

 

 

number is printed in the xx field

 

 

of the log record header. This is

 

 

an NSARPA internal error.

 

 

 

 

Logging Codes and Messages 647