HELLO/BYE Error Codes

These error codes are returned in the err parameter of the utility subroutines HELLO and BYE.

HELLO/BYE Error Codes

Code

Meaning

Action

 

 

 

0

No error.

No action is necessary.

 

 

 

1

HELLO failure or line

Try again or report error to the

 

disconnected.

Network Manager.

 

 

 

4

Invalid LU: The LU specified is

Check parameters and try

 

not a communications line to an

again.

 

HP 3000, or the NS/3000

 

 

modules are not initialized.

 

 

 

 

5

Timeout.

Try again.

 

 

 

6

Illegal (rejected) request.

Check syntax and try again.

 

Request is not recognized.

 

 

 

 

7

Transaction Table access error

See NSINF and DSMOD in the

 

(not enough Transaction Control

NSARPA/1000 Generation and

 

Blocks for HELLO).

Initialization Manual.

 

 

 

8

NonNSARPA error (for

Check syntax. If OK, consult

 

example, inputonly device

your Network Manager.

 

specified as list LU).

 

 

 

 

Numeric Error Codes 29