Message

Meaning

Action

 

 

 

Internal NFT error

An internal NFT error has

This error requires HP

(NS/NFTERR 1)

occurred.

notification.

 

 

 

Unable to logon to

An error occurred in logging on

This error may require one of the

source computer

to the source computer, or no

following actions: (1) If an

(NS/NFTERR 2)

logon string was given when

additional error message is

 

one was required.

returned, refer to it for further

 

 

information; (2) check the logon

 

 

string and try again; or (3)

 

 

provide a different logon string

 

 

and try again.

 

 

 

Unable to logon to

An error occurred in logging on

This error may require one of the

target computer

to the target computer, or no

following actions: (1) If an

(NS/NFTERR 3)

logon string was given when

additional error message is

 

one was required.

returned, refer to it for further

 

 

information; (2) check the logon

 

 

string and try again; or (3)

 

 

provide a different logon string

 

 

and try again.

 

 

 

Unable to open or access

A file system error occurred in

Verify that the source file exists

source file or device

opening or accessing the

and is accessible. Also, refer to

(NS/NFTERR 4)

source file. Either (1) a

the qualifying file system error

 

protection violation occurred in

string.

 

accessing the source file or its

 

 

directory or (2) the source file

 

 

name specifies an unsupported

 

 

device.

 

 

 

 

Unable to connect to

A connection could not be

Verify that the source computer

source computer

established to the computer

name is correct, that the source

(NS/NFTERR 5)

where the source file resides.

computer is connected to the

 

Either the source computer

network, that the source node

 

name is incorrect, the source

has its own entry in the Nodal

 

computer is not connected to

Registry, that there are sufficient

 

the network, there are

resources to establish a

 

insufficient resources, or NFT

connection, or that NFT has

 

has not been initialized on the

been initialized on the source

 

source computer.

computer. Also, refer to the

 

 

qualifying error string.

 

 

 

Unable to connect to

A connection could not be

Verify that the target computer

target computer

established to the computer

name is correct, that the target

(NS/NFTERR 6)

where the target file resides.

computer is connected to the

 

Often means Probe failed on the

network, that there are sufficient

 

LAN, or the target computer was

resources to establish a

 

not in the local Nodal Registry.

connection, or that NFT has

 

Either the target computer name

been initialized on the target

 

is incorrect, the target computer

computer. Also, refer to the

 

is not connected to the network,

qualifying error string.

 

there are insufficient resources,

 

 

or NFT has not been initialized

 

 

on the target computer.

 

 

 

 

Insufficient resources

There are insufficient resources

Verify that there are sufficient

at source computer

at the source computer to copy

resources on the source

(NS/NFTERR 7)

the file or files. Refer to the

computer and try again.

 

qualifying error string.

 

 

 

 

Program Specific Error Messages 411