DSMOD Error Messages

The following error messages are returned to the current log device when an error is encountered by the program DSMOD.

DSMOD Error Messages

Message

Meaning

Action

 

 

 

/DSMOD: CLASS I/O ERROR

A required class number cannot

This error may require

 

be allocated. DSMOD is

regeneration with a larger

 

aborted.

allotment of class numbers.

 

 

 

/DSMOD: DSMOD ABORTED

/A command entered or

Explanation will have been

 

irrecoverable error occurred.

printed prior to this message. If

 

 

input from a file, line number of

 

 

last error also printed.

 

 

 

/DSMOD: END DSMOD

Normal completion message.

No action is necessary.

 

The ten characters comprising

 

 

the message are also returned

 

 

in the 5word temporary storage

 

 

area of a scheduler's ID

 

 

segment. They may be

 

 

recovered through the use of

 

 

RMPAR. If DSMOD has been

 

 

aborted, the five words returned

 

 

are: 100000B,ER,D,SM,OD.

 

 

 

 

/DSMOD: ERROR: MON?:

The specified monitor XXXXX is

Load the monitor, then use

XXXXX

not in the system.

DSMOD to schedule it.

 

 

 

/DSMOD: ERROR: STAT:

The monitor's status is not

Abort DSMOD using the /A

XXXXX

•dormant" and therefore it

command and then use RTE

 

cannot be scheduled.

operator commands to change

 

 

the status.

 

 

 

/DSMOD: FILE ERROR

Improper response to •INPUT #

Retry.

 

OF FILES".

 

 

 

 

/DSMOD: INVALID NAME!

Monitor name is not recognized

Retry.

 

by DSMOD.

 

 

 

 

/DSMOD: INVALID

Operator entry error.

Retry.

RESPONSE!

 

 

 

 

 

/DSMOD: LU ERROR

Improper LU number specified

Retry.

 

or LU number does not point to

 

 

the communication driver.

 

 

 

 

/DSMOD: LU ERROR: “/L”

The line reenable command

You must use the DI command

NOT VALID FOR X.25 POOL

(/L) cannot be used to

to disable the LU and return it to

LUS. USE DSMOD “DI” TO

reenable an X.25 pool LU.

the pool.

DISABLE THE LU

 

 

 

 

 

/DSMOD: NODE SPEC. ERROR

Improper nodal reference value.

Correct initialization answers

 

DSMOD aborted.

and restart DSMOD.

 

 

 

/DSMOD: READ ERROR

Endoffile or FMGR error has

The question is repeated on the

 

been detected on the input

(error LU) device. The user may

 

device/file.

supply the required response

 

 

from this device.

 

 

 

Program Specific Error Messages 419