LogMessage

Meaning

Action

 

 

 

1017

(Memory Manager) Resources

This error requires HP

 

still active in socket buffer.

notification.

 

Buffers are still in use. This is an

 

 

NSARPA internal error.

 

 

 

 

1018

(Memory Manager) There is

This error requires HP

 

enough memory between the

notification.

 

user's SBUF and the pool to

 

 

satisfy the request, but it is

 

 

currently being used. This is an

 

 

NSARPA internal error.

 

 

 

 

1019

(Memory Manager) A parity error

If communications are severely

 

was discovered in a buffer on

affected, reinitialize

 

the MBUF chain.

NSARPA/1000, moving DSAM

 

 

to unaffected memory, or

 

 

replace the defective memory.

 

 

 

1020

(Memory Manager) The SBUF

This error requires HP

 

reference did not reference a

notification.

 

valid SBUF. This may occur if

 

 

the reference did not point to a

 

 

valid SBUF, or the SBUF was not

 

 

initialized, or the SBUF was

 

 

disposing, or the SBUF was a

 

 

pool SBUF. This is an NSARPA

 

 

internal error.

 

 

 

 

1021

(Memory Manager) The SBUF is

This error requires HP

 

already initialized. This is an

notification.

 

NSARPA internal error.

 

 

 

 

1022

(Memory Manager) Either no

If this error occurred in the event

 

data is currently available or it

log and the system is busy, no

 

may be possible to get that

action is necessary. However, if

 

many memory credits from the

throughput is significantly

 

individual SBUF (not using the

affected, or if connections are

 

pools), but currently they are in

lost, then the size of DSAM

 

use. This error was returned to

should be increased.

 

an NSARPA/1000 protocol

 

 

handler. In most cases, the

 

 

protocol handler will have to

 

 

dispose of the memory.

 

 

 

 

1023

(Memory Manager) The number

If this error occurred in the event

 

of memory credits required will

log and the system is busy, no

 

never be available. This error

action is necessary. However, if

 

was returned to an

throughput is significantly

 

NSARPA/1000 protocol handler.

affected, or if connections are

 

In most cases, the protocol

lost, then the size of DSAM

 

handler will have to dispose of

should be increased.

 

the memory.

 

 

 

 

1024

(Memory Manager) The MBUF

This error requires HP

 

chain contains an illegal account

notification.

 

given the operation requested.

 

 

This is an NSARPA internal

 

 

error.

 

 

 

 

618 Logging Codes and Messages