LogMessage | Meaning | Action |
|
|
|
1017 | (Memory Manager) Resources | This error requires HP |
| still active in socket buffer. | notification. |
| Buffers are still in use. This is an |
|
| NSARPA internal error. |
|
|
|
|
1018 | (Memory Manager) There is | This error requires HP |
| enough memory between the | notification. |
| user's SBUF and the pool to |
|
| satisfy the request, but it is |
|
| currently being used. This is an |
|
| NSARPA internal error. |
|
|
|
|
1019 | (Memory Manager) A parity error | If communications are severely |
| was discovered in a buffer on | affected, reinitialize |
| the MBUF chain. | NSARPA/1000, moving DSAM |
|
| to unaffected memory, or |
|
| replace the defective memory. |
|
|
|
1020 | (Memory Manager) The SBUF | This error requires HP |
| reference did not reference a | notification. |
| valid SBUF. This may occur if |
|
| the reference did not point to a |
|
| valid SBUF, or the SBUF was not |
|
| initialized, or the SBUF was |
|
| disposing, or the SBUF was a |
|
| pool SBUF. This is an NSARPA |
|
| internal error. |
|
|
|
|
1021 | (Memory Manager) The SBUF is | This error requires HP |
| already initialized. This is an | notification. |
| NSARPA internal error. |
|
|
|
|
1022 | (Memory Manager) Either no | If this error occurred in the event |
| data is currently available or it | log and the system is busy, no |
| may be possible to get that | action is necessary. However, if |
| many memory credits from the | throughput is significantly |
| individual SBUF (not using the | affected, or if connections are |
| pools), but currently they are in | lost, then the size of DSAM |
| use. This error was returned to | should be increased. |
| an NSARPA/1000 protocol |
|
| handler. In most cases, the |
|
| protocol handler will have to |
|
| dispose of the memory. |
|
|
|
|
1023 | (Memory Manager) The number | If this error occurred in the event |
| of memory credits required will | log and the system is busy, no |
| never be available. This error | action is necessary. However, if |
| was returned to an | throughput is significantly |
| NSARPA/1000 protocol handler. | affected, or if connections are |
| In most cases, the protocol | lost, then the size of DSAM |
| handler will have to dispose of | should be increased. |
| the memory. |
|
|
|
|
1024 | (Memory Manager) The MBUF | This error requires HP |
| chain contains an illegal account | notification. |
| given the operation requested. |
|
| This is an NSARPA internal |
|
| error. |
|
|
|
|
618 Logging Codes and Messages