Network Configuration page. The name is displayed as Broadcom Corporation, Unknown device instead of HP Ethernet 1Gb 4-port331i-SPI Adapter.

Suggested action

No action required.

Unable to launch server migration tools from Systems Insight Manager

When you launch server migration tools from Systems Insight Manager, the system displays the following error message:

An Exception occurred. SSO Validation Failed. Try launching again from

HP SIM.

VMwareDisconnectTimeout = 300000

Suggested Action

Perform the following steps:

1.In the hpvmm.conf file (<Insight Control server migration Installation Folder>\bin), add the following:

VMwareDisconnectTimeout = 300000

2.Save the file and restart the server migration services.

NOTE: If this issue occurs again, change the VMwareDisconnectTimeout value from 300000 to 600000.

Static IP configuration fails on Hyper-V VM when configured using Boot CD

When you perform a Manual Boot operation using the Insight Control server migration Boot CD for VMs on Microsoft Windows Server 2008 R2 with Hyper-V and Microsoft Windows Server 2012 with Hyper-V, and configure static IP on the Network configuration page, the following error is displayed:

Selected Network Card doesn't have link - verify you have chosen the correct device.

Cause

Static IP configuration fails on Microsoft Windows Server 2008 R2 with Hyper-V and Microsoft Windows Server 2012 with Hyper-V.

Suggested action:

To resolve this issue, perform one of the following:

Use the Auto boot option and enter the desired IP address in the step 3 of the Insight Control server migration wizard.

For Manual Boot option, select the required option on the Network configuration page to configure dynamic IP using DHCP.

Unable to migrate Windows 2008/2008 R2/2012 using Windows 2008 x64 CMS

Cause

Deployment Image Servicing and Management (DISM) tool is unavailable on the CMS.

Suggested Action

To resolve the issue, perform the following steps:

50 Troubleshooting