Out of memory error occurs on the application station during migration

The Insight Control application station requires a minimum of 1024 MB of free memory for Insight Control migrations.

Suggested action

Free memory or add memory to the application station, and then restart the migration.

Destination server boots with an invalid IP address

After a P2P migration, the destination server might boot with an invalid IP address (for example, 169.x.x.x), instead of using the IP address that was configured through the migration wizard.

Cause

This issue occurs if the destination IP address configuration fails or Dynamic Host Configuration Protocol (DHCP) is not enabled in the network. Whenever a NIC is added to the server, by default the NIC is assigned an IP address using the DHCP configuration. If no DHCP server is configured on the network, the server will boot with an invalid IP address.

Suggested action

After the P2P migration is complete, manually configure the IP address on the destination server. For specific instructions on performing this task, see the help files for the specific OS documentation.

Windows server migration Source Agent or PINT remote deployment is intermittent and deployment fails with a General failure occurred error

When you remotely deploy the Windows server migration Source Agent or PINT from the Insight Control server migration application station or from Systems Insight Manager, server migration Source Agent deployment fails with the error General failure occurred. In addition, the

<Insight Control server migration Installation

Folder>\log\AgentLogs\hp\log\<source IP>\timestamp_smp_log.txt file displays

the following exception:

Received Target Exception: UnknownException : SoapSession::SoapSession : unknown exception! No install was run, due to connection error

Suggested action

Manually install the server migration Source Agent or PINT on the source server.

Unable to detect HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter configured as iSCSI disk in step 5 of migration wizard

When you start a P2P migration of any of the OS from any server to DL385p Gen8 with HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter configured as iSCSI disk and then start an auto boot in step 3, you will observe that the adapter is not detected in step 5 of migration wizard and the following error message is displayed:

"HP Insight Control could not find any disks on destination server"

Suggested action

You must disable IOMMU in RBSU (System Config > Processor Settings > AMD–Vi).

HP Smart Array B320i controller name is not displayed

When you perform X2P migration to Gen8 server having HP Smart Array B320i as primary Controller, you will observe that the name of controller is not displayed in step 5 and 7 of the migration wizard.

64 Troubleshooting