Suggested action

Assign a different IP address to the network adaptor or reboot the server.

Supported storage controllers display Unknown on the Boot CD ISO

Cause

If the Insight Control server migration Boot CD ISO blocks the supported storage controllers for P2P or V2P migrations, the controller might appear as Unknown.

Suggested action

To reset NVRAM on the destination server:

1.Reboot the destination server.

2.Press F9 during reboot to enter ROM-Based Setup Utility (RBSU).

3.Open Advanced Options, and then select Restore Settings/Erase Boot Disk or Clear NVRAM.

4.Reboot the system by using the Insight Control server migration Boot CD ISO. The proper storage controller name is detected.

Automatic booting of the destination physical server fails

The destination server does not boot and no error message appears on the application station.

Suggested action

Reset the iLO network settings of the destination server and retry the automatic booting of the destination server.

3 Insight Control server migration might not detect virtual machines on mapped network drives

Cause

Insight Control server migration cannot locate virtual machines stored on mapped network drives if the service does not have access to the network shares.

Suggested action

Manually migrate these disks after a successful migration.

Destination server does not boot even though the automatic booting option was chosen during X2P migrations

During X2P migrations, if the automatic booting option was chosen during the Identify Destination Server step of the migration wizard and if the destination server does not boot, either of the following scenarios might occur:

Automatic booting fails with the following error in the migration wizard: Could not get timely response from remote management. Please try again or use manual boot option.

Automatic booting continues for more than 40 minutes without any error messages displayed in the migration wizard.

Suggested action

Reset the iLO network settings on the destination server, and then retry the automatic booting or manually boot the destination server. For more information on iLO, see the iLO user guide.

Destination preparation

57