After the issue is resolved, any disk can be added (which might involve upgrading the virtual hardware on the virtual machine.)

Server is unresponsive during PSP installation

The server becomes unresponsive during PSP installation.

Suggested action

Reboot the server and then reinstall PSP manually.

Destination server still shows server migration UI but server migration wizard shows migration completed

After the migration, server migration loses connectivity to the Hyper-V host, which causes server migration to fail to eject the boot CD and reboot the VM. If server migration cannot connect to the Hyper-V host, reboot by using the destination agent. In this case, server migration will be unable to eject the boot CD and as a result, after the reboot, the VM will boot back into the boot CD. This issue is specific to Microsoft Hyper-V VMs.

Suggested action

Manually eject the virtual boot CD from the VM and reboot the VM.

Operating system is not booting on a destination server that has SAN disks

After you perform a successful P2P migration of the SLES 11 SP1 32-bit operating system on SAN disks with Brocade or QLogic Fibre Channel HBA as the primary boot controller, the operating system does not boot on the destination server.

Suggested action

Before you migrate any Linux distribution to a destination server that has SAN storage, make sure that the RPM package containing firmware files (such as brocade-firmware-<version>.noarch.rpmand qlogic-firmware-<version>.noarch.rpmon SLES OS, and ql2xxx-firmware-<version>.noarch.rpmon RHEL OS) for the target SAN Fibre Channel HBA are installed on the source server from the OS installation media.

Error is displayed for a missing file system while migrated Linux OS is booted on the destination server

When you migrate a file system to the destination server multiple times, the multiple file systems that contain the same UUID are created.

Suggested action

Make sure that multipath is configured on the source server. If multipath is not configured, make sure that the file systems that are being migrated do not have the same UUID.

Logical drives of HP Smart Array B110i SATA RAID Controller are removed

After a successful X2P migration of the Windows Server 2008 OS, the logical drives of HP Smart Array B110i SATA RAID Controller are removed.

Suggested action

When the logical drives are removed, you must re-create the exact logical drives by using ACU or ORCA on the destination server after migration.

70 Troubleshooting

Page 70
Image 70
HP PART NUMBER: 461487-401A manual Server is unresponsive during PSP installation