11.If you do not want to use CHAP as an authentication method, exit the CN1100E setup screens and reboot now.

If you would like to use CHAP as an authentication method, return to the Add/Ping iSCSI Target screen as shown in “Adding an iSCSI Target” (page 27), select Authentication Method, and then choose one of the following options:

Select One-Way CHAP (see “One-Way CHAP” (page 28)). Figure 7 One-Way CHAP

The CHAP Configuration screen appears (see “CHAP Configuration for One-Way CHAP” (page 28)).

Figure 8 CHAP Configuration for One-Way CHAP

Fill in the Target CHAP Name (the initiator IQN name) and Target Secret, then click OK.

In the Authentication Method setting on the Add-Ping iSCSI Target screen (“One-Way CHAP” (page 28)), select Mutual CHAP. The CHAP Configuration screen appears (see “CHAP Configuration for Mutual CHAP” (page 29)).

28 Configuring the HP 3PAR StoreServ Storage for iSCSI