3 Configuring the HP 3PAR StoreServ Storage for iSCSI

3 Configuring the HP 3PAR StoreServ Storage for iSCSI

This chapter explains how to establish an iSCSI connection between the HP 3PAR StoreServ Storage and the VMware ESX host. If you are running specific CNA cards, a software or hardware iSCSI initiator can be used. For details about hardware iSCSI configuration, see “Hardware iSCSI Support” (page 25).

Software iSCSI Support

Setting Up the Ports for an iSCSI Connection

To establish an iSCSI connection between the HP 3PAR StoreServ Storage and the ESX host, you need to set up each HP 3PAR StoreServ Storage iSCSI target port that will be connected to an iSCSI initiator as described in the following steps.

1.A 10 Gb iSCSI connection, which is supported in the HP 3PAR StoreServ 10000 Storage and the HP 3PAR StoreServ 7000 Storage, requires a one-time configuration using the controlport command.

Issue the showport and showport -icommands to check the current CNA configuration. For example:

#showport

N:S:P

Mode

State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol

0:1:1 suspended config_wait

-

-

cna

-

1:1:1 suspended config_wait

-

-

cna

-

#showport -i

N:S:P Brand

Model

Rev

Firmware

Serial

HWType

0:1:1 QLOGIC

QLE8242

58

0.0.0.0

PCGLT0ARC1K3SK CNA

1:1:1 QLOGIC

QLE8242

58

0.0.0.0

PCGLT0ARC1K3SK CNA

2.If State=config_wait or Firmware=0.0.0.0, use the controlport config iscsi <n:s:p> command to configure, and then use the showport and showport -i commands to verify the configuration setting.

For example:

#controlport config iscsi 0:1:1

#controlport config iscsi 1:1:1

#showport

N:S:P

Mode

State ----Node_WWN---- -Port_WWN/HW_Addr- Type Protocol

...

 

 

 

 

 

 

0:1:1

target

ready

 

-

2C27D7521F3E iscsi

iSCSI

...

 

 

 

 

 

 

1:1:1

target

ready

 

-

2C27D7521F3A iscsi

iSCSI

# showport -i

 

 

 

 

 

...

 

 

 

 

 

 

N:S:P Brand Model

Rev Firmware

Serial

HWType

 

...

 

 

 

 

 

 

0:1:1 QLOGIC QLE8242

58

4.8.76.48015 PCGLT0ARC1K3SK CNA

 

1:1:1 QLOGIC QLE8242

58

4.8.76.48015 PCGLT0ARC1K3SK CNA

 