NOTE: If changing the config from iSCSI to FCoE, follow the steps below.
1.Issue the showportcommand.
#showport
0:3:1 | target | ready | - | 000E1E05BEE6 | iscsi | iSCSI | - | - | - |
0:3:2 | target | ready | - | 000E1E05BEE2 | iscsi | iSCSI | - | - | - |
2.Turn off the iSCSI ports:
#controlport offline 0:3:1
#controlport offline 0:3:2
showport
0:3:1 target offline - 000E1E05BEE2 iscsi iSCSI0:3:2 target offline - 000E1E05BEE2 iscsi iSCSI
3.Change the topology to FCoE:
#controlport config fcoe 0:3:1
#controlport config fcoe 0:3:2
controlport rst 0:3:1 controlport rst 0:3:2
0:3:1 target offline - 000E1E05BEE2 iscsi iSCSI0:3:2 target offline - 000E1E05BEE2 iscsi iSCSI
showport
0:3:1 | target | ready 2FF70002AC000121 | 20310002AC000121 | host | FCoE |
- | - | - |
|
|
|
0:3:2 | target | ready 2FF70002AC000121 | 20320002AC000121 | free | FCoE |
- | - | - |
|
|
|
4.Check the current settings of the FCoE ports by issuing showport
#showport -fcoe
N:S:P ENode_MAC_Address PFC_Mask
0:3:1 | 0x08 | |
0:3:2 | 0x00 |
32 Configuring the HP 3PAR StoreServ Storage for FCoE