HP QR516B manual Turn off the iSCSI ports, # controlport offline Showport

Models: QR516B

1 89
Download 89 pages 22 Kb
Page 32
Image 32

NOTE: If changing the config from iSCSI to FCoE, follow the steps below.

1.Issue the showportcommand.

#showport

0:3:1

target

ready

-

000E1E05BEE6

iscsi

iSCSI

-

-

-

0:3:2

target

ready

-

000E1E05BEE2

iscsi

iSCSI

-

-

-

2.Turn off the iSCSI ports:

#controlport offline 0:3:1

#controlport offline 0:3:2

showport

0:3:1 target offline - 000E1E05BEE2 iscsi iSCSI0:3:2 target offline - 000E1E05BEE2 iscsi iSCSI

3.Change the topology to FCoE:

#controlport config fcoe 0:3:1

#controlport config fcoe 0:3:2

controlport rst 0:3:1 controlport rst 0:3:2

0:3:1 target offline - 000E1E05BEE2 iscsi iSCSI0:3:2 target offline - 000E1E05BEE2 iscsi iSCSI

showport

0:3:1

target

ready 2FF70002AC000121

20310002AC000121

host

FCoE

-

-

-

 

 

 

0:3:2

target

ready 2FF70002AC000121

20320002AC000121

free

FCoE

-

-

-

 

 

 

4.Check the current settings of the FCoE ports by issuing showport -fcoe. For example:

#showport -fcoe

N:S:P ENode_MAC_Address PFC_Mask

0:3:1

00-02-AC-07-01-21

0x08

0:3:2

00-02-AC-06-01-21

0x00

32 Configuring the HP 3PAR StoreServ Storage for FCoE

Page 32
Image 32