Chapter 3 Operation

RIC-155Installation and Operation Manual

 

 

 

 

 

 

 

 

 

Parameter

Default Value

 

 

 

 

 

Flow control

Enable

 

 

 

 

 

Ethernet mode

Full duplex

 

 

 

 

 

LAN speed

100 Mbps

 

 

 

 

 

Uplink

 

 

 

 

 

 

 

Frame type

SONET

 

 

 

 

 

BER threshold

Disable

 

 

 

 

 

EED threshold

10E-3

 

 

SD threshold

10E-6

 

 

J1 Tx path trace enable

Disable

 

 

 

 

 

J1 path trace

 

 

 

 

 

 

 

Physical Failure Forwarding

Disable

 

 

 

 

 

Bridge

 

 

 

 

 

 

 

Aging Time

304

 

 

 

 

 

 

Forwarding Mode

Filter

 

 

 

 

 

Statistics Counted

OK only

 

 

 

 

 

Multicast & Broadcast Rate

No Limit

 

Limit

 

 

 

 

 

 

 

DATA Port PVID

2

 

 

 

 

 

 

DATA Port PVID Priority

0

 

 

 

 

 

 

DATA Port Tag Stripping

No

 

 

 

 

 

MNG Port PVID

1

 

 

 

 

 

 

MNG Port PVID Priority

0

 

 

 

 

 

 

MNG Port Tag Stripping

No

 

 

 

 

 

POS Port Egress

Unmodified

 

 

 

 

3.4Configuration Alternatives

Managing RIC-155 via Terminal Port

RIC-155 includes a V.24/RS-232 asynchronous DTE port, designated CONTROL and terminated in a 9-pin D-type female connector. The control port continuously monitors the incoming data stream and immediately responds to any input string received through this port. The port requires a cross-cable for the ASCII terminal connection.

The RIC-155 control port can be configured to communicate at the following rates: 9.6, 19.2, 38.4, 57.6 or 115.2 kbps. When running a terminal control

3-4

Configuration Alternatives

Page 30
Image 30
RAD Data comm Configuration Alternatives, Managing RIC-155 via Terminal Port, Parameter Default Value, Uplink, Bridge