Chapter 2

Installation and Setup

2.1Introduction

This chapter describes installation and setup procedures for the standalone RIC-155 device.

After installing the unit:

Refer to Chapter 3 for the operating instructions.

Refer to Chapter 4 for the detailed system configuration procedures using an ASCII terminal connected to the RIC-155 control port.

If a problem is encountered, refer to Chapter 5 for test and diagnostic instructions.

The RIC-155 standalone unit is designed for desktop or bench installation and is delivered as a fully assembled unit. No provisions are made for bolting the unit to a tabletop.

Always observe standard safety precautions during installation, operation, and maintenance of this product.

Warning

2.2Site Requirements and Prerequisites

AC-powered RIC-155 units should be installed within 1.5m (5 ft) of an easily-accessible grounded AC outlet capable of furnishing the voltage in accordance with RIC-155 nominal supply voltage.

DC-powered RIC-155 unit requires a -48 VDC or 24 VDC power source, which must be adequately isolated from the main supply.

Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables.

The ambient operating temperature of RIC-155 should be 0 to 50°C (32 to 122°F), at a relative of up to 90%, non-condensing. humidity

Site Requirements and Prerequisites

2-1

Page 23
Image 23
RAD Data comm RIC-155 operation manual Chapter Installation and Setup, Introduction, Site Requirements and Prerequisites