RIC-155 Installation and Operation Manual Chapter 4 Configuration
Configuring the RIC-155 for Operation 4-7
To display the System Configuration menu:
From the Configuration menu, select System Configuration.
The System Configuration menu appears (see Figure 4-9).
Procedures for alarm configuration and masking are detailed in Chapter 5.
RIC-155
System
1. Master clock >
2. Management >
3. Control port >
4. Alarm Configuration >
5. Factory default >
6. Reset Device >
>
Please select item <1 to 5>
ESC-prev.menu; !-main menu; &-exit
Figure 4-9. System Configuration Menu
Configuring the Clock Source
RIC-155 supports internal and loopback clock modes.
To configure the clock source:
From the System Configuration menu, select Master Clock.
Display is refreshed and a new master clock value appears: Internal or
Loopback.
Configuring Control Port Parameters
RIC-155 embedded software enables you to configure the serial port parameters,
which include specifying terminal baud rate, defining user name, password and
log-off time, and enabling or disabling pop-up alarms.
To access the Control port menu:
From the System Configuration menu, select Control Port.
The Control Port menu appears (see Figure 4-10).
RIC-155
Control Port
1. Baud Rate >(9600)
2. Pop Alarm (OFF)
3. Security Timeout (10 min)
4. Save All
>
Please select item <1 to 4>
ESC-prev.menu; !-main menu; &-exit
Figure 4-10. Control Port Menu