RIC-155Installation and Operation Manual

Chapter 4 Configuration

 

 

 

 

 

 

 

 

 

 

 

RIC-155

 

Manager List

IP address

Trap Mask

 

Manager ID

 

1.

0.0.0.0

NO

 

2.

0.0.0.0

NO

 

3.

0.0.0.0

NO

 

4.

0.0.0.0

NO

 

5.

0.0.0.0

YES

 

ESC-prev.menu; !-main menu;

&-exit; ?-help

 

 

 

 

Figure 4-6. Manager List Menu

Controlling the Management Access

You can enable or disable access to the RIC-155 management system via SNMP, Telnet or Web-based applications. By disabling SNMP, Telnet or Web, you prevent unauthorized access to the system when security of the RIC-155 IP address has been compromised. When SNMP, Telnet and Web access is disabled, RIC-155 can be managed via an ASCII terminal only. In addition, you can enable or disable an inband management (via uplink or DATA port) or out-of-band (via MNG port).

To define the management access method:

1.Follow the path: Configuration > System Configuration > Management > Management Access.

The Management Access menu appears.

2.From the Management Access menu, select TELNET Access to configure Telnet access, select SNMP Access to configure SNMP access, or select WEB Access to configure Web access.

A TELNET Access, SNMP Access or WEB Access menu appears (see Figure 4-7).

Note During a Telnet session, Telnet Access is masked.

During a SNMP session, SNMP Access is masked.

During a Web session, Web Access is masked.

3.From the TELNET Access, SNMP Access or WEB Access menu, select ENABLE to allow selected management type, DISABLE to restrict it, or Managers Only to allow access only for the management stations defined in the Manager List menu (see Figure 4-6).

4.If the Web management (ConfiguRAD) is enabled, you can select WEB Trace Refresh from the Management Access menu, and define refresh rate of the Trace pane in seconds (1255).

Configuring RIC-155 for Management

4-5

Page 41
Image 41
RAD Data comm RIC-155 operation manual Controlling the Management Access, To define the management access method