RIC-155Installation and Operation Manual

Chapter 4 Configuration

 

 

The Software Version screen appears (see Figure 4-24).

SW files

RIC-155

 

Software active version:

1.00

Software active partition:

0

Code size:

190

Date:

28-02-03

Software backup version:

0.00n00

Software backup partition:

1

Code size:

0

Date:

0-0-0

Boot version:

2.20

Boot mng version:

4.00

SW Files Table

ESC-prev.menu; !-main menu; &-exit

Figure 4-24. Software Version Screen

Switching Software Versions

If the active software becomes corrupted, you can switch it with the backup file.

To switch software versions:

1. From the File System menu, select Swap SW Files. RIC-155 displays the following message:

Request to swap SW files!!! Are you sure? Y/N

2. Type Y to confirm the file swap.

RIC-155 performs the swap and sends the following string:

Program Switching

The active software becomes backup and vice versa. At this stage, RIC-155 is automatically reset.

If you try to switch the software versions when only one version is available, RIC-155 responds with the following message:

Impossible to switch – no other program

Press any key to continue

Resetting RIC-155

RIC-155 supports two types of reset:

Reset to the default setting Resetting all parameters

Resetting all parameters, except for master clock and management options

Overall reset of the device.