Chapter 5 Troubleshooting and Diagnostics

RIC-155Installation and Operation Manual

 

 

To display SDH/SONET statistics for all intervals:

1. From the Uplink Statistics menu (Figure 5-3), select Intervals Statistics to

 

 

 

 

 

 

display the SDH/SONET for all 15-minute intervals.

 

 

 

 

 

 

 

 

 

 

 

The first page of the Uplink Interval Statistics screen appears (see Figure 5-6).

 

 

 

 

 

2. Scroll right (R) and left (L) to navigate between statistics screens for interval 1 to

 

 

 

 

 

 

interval 9 (see Figure 5-7and Figure 5-8).

 

 

 

 

 

 

 

 

 

 

 

Table 5-1explains all SDH/SONET statistics parameters.

 

 

 

 

 

 

 

 

 

3. Scroll up (U) and down (D) to display statistic data for the rest of the intervals.

 

 

 

Note

 

 

 

 

 

 

In the Uplink Interval Statistics screen the following abbreviations are used:

 

 

 

 

 

 

 

S – section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L – line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P – path

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FE – far end.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For example, SES_LFE means Line Severely Errored Seconds Far End.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Uplink Interval Statistics

 

 

RIC-155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval

LOS

CV_S

ES_S SES_S

SEF_S

CV_L

ES_L

SES_L

UAS_L

CV_LFE ES_LFE SES_LFE

 

1

 

4

0

 

10

10

6

10

5

0

10

10

6

9

 

 

2

 

5

0

 

10

9

6

10

5

0

10

10

6

9

 

3

 

7

0

 

10

6

9

4

4

0

10

10

6

9

 

V 4

 

2

0

 

10

7

9

4

4

0

10

10

6

9

 

 

5

 

6

0

 

10

10

6

10

5

0

10

10

6

9

 

 

6

 

5

0

 

10

10

9

4

4

0

10

10

6

6

 

 

7

 

6

0

 

10

10

9

4

4

0

10

10

6

9

 

 

8

 

4

0

 

10

9

4

10

4

0

10

10

6

9

 

 

9

 

3

0

 

10

8

9

10

4

4

0

10

10

6

 

->>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESC-prev.menu; !-main menu; &-exit;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5-6. Uplink Interval Statistics, Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Uplink Interval Statistics

 

 

RIC-155

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

UAS_LFE CV_P

ES_P

SES_P

UAS_P

CV_PFE

ES_PFE

SES_PFE

UAS_PFE

 

 

 

4

0

 

10

 

10

6

9

0

 

0

10

 

 

 

2

5

0

 

10

 

9

6

9

0

 

0

10

 

 

 

3

7

0

 

10

 

6

9

10

0

 

10

10

 

 

 

V

4

2

0

 

10

 

7

9

10

0

 

10

10

 

 

 

 

5

6

0

 

10

 

10

6

9

0

 

10

10

 

 

 

 

6

5

0

 

10

 

10

9

10

0

 

10

10

 

 

 

 

7

6

0

 

10

 

10

9

10

0

 

10

10

 

 

 

 

8

4

0

 

10

 

9

9

10

0

 

10

10

 

 

 

 

9

3

0

 

10

 

8

9

10

0

 

10

0

 

 

 

->>

ESC-prev.menu; !-main menu; &-exit;

Figure 5-7. Uplink Interval Statistics, Page 2

5-6

Monitoring Performance

Page 66
Image 66
RAD Data comm RIC-155 To display SDH/SONET statistics for all intervals, 1explains all SDH/SONET statistics parameters