RIC-155 Installation and Operation Manual Chapter 5 Troubleshooting and Diagnostics
Handling Alarms 5-11
Terminal Message Description Severity
Path Remote Defect
Indication
Path Remote Defect Indication signal is detected Minor
Path Excessive Error
Defect
Number of the Path Excessive Error Defect errors exceeds
threshold
Major
Path Signal Degraded
Error
Number of Path Signal Degraded Errors exceeds threshold Major
Path Trace J1 string
mismatch
Rx path trace information mismatch is detected Major
Uplink port signal loss Receive signal loss is detected on the uplink Major
Data 1 Ethernet port
down
Data integrity failure is detected at the primary Ethernet port Major
Management Ethernet
port down
Data integrity failure is detected at the management port Major
Table 5-3. RIC-155 Events
Number Terminal Message Description
23 Downloading... Software download has started
24 Downloading failure Software download has failed
25 User password has been
changed
User password has been changed
27 User login has been
changed
User name has been changed
32 Alarm log is full More than 200 entries registered in the alarm log file