Chapter 5 Troubleshooting and Diagnostics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Message

Description

 

Severity

 

 

 

 

 

 

Path Remote Defect

Path Remote Defect Indication signal is detected

Minor

Indication

 

 

 

 

 

 

 

 

 

 

 

Path Excessive Error

Number of the Path Excessive Error Defect errors exceeds

Major

Defect

threshold

 

 

 

 

 

 

 

 

 

 

Path Signal Degraded

Number of Path Signal Degraded Errors exceeds threshold

Major

Error

 

 

 

 

 

 

 

 

 

 

 

Path Trace J1 string

Rx path trace information mismatch is detected

Major

mismatch

 

 

 

 

 

 

 

 

 

 

 

Uplink port signal loss

Receive signal loss is detected on the uplink

Major

 

 

 

 

 

 

Data 1 Ethernet port

Data integrity failure is detected at the primary Ethernet port

Major

down

 

 

 

 

 

 

 

 

 

 

 

Management Ethernet

Data integrity failure is detected at the management port

Major

port down

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5-3. RIC-155 Events

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

Terminal Message

Description

 

 

 

 

 

 

 

 

 

 

23

Downloading...

Software download has started

 

 

 

 

 

 

 

 

 

 

24

Downloading failure

Software download has failed

 

 

 

 

 

 

 

 

 

 

25

User password has been

User password has been changed

 

 

 

 

 

 

changed

 

 

 

 

 

 

 

 

 

 

 

27

User login has been

User name has been changed

 

 

 

 

 

 

changed

 

 

 

 

 

 

 

 

 

32

Alarm log is full

More than 200 entries registered in the alarm log file

 

 

 

 

 

 

 

 

Handling Alarms

5-11

Page 71
Image 71
RAD Data comm operation manual RIC-155 Events, Number Terminal Message Description