RIC-155Installation and Operation Manual

Chapter 5 Troubleshooting and Diagnostics

 

 

 

 

 

 

 

 

Uplink Statistics

 

RIC-155

 

...(6)

Far End Line ESs

... (7)

Time Elapsed

LOS

... (0)

Far End Line SES

... (5)

Section CV

... (6)

Far End Line UASs

... (6)

Section ESs

... (6)

Path CV

... (2)

Section SESs

... (6)

Path ESs

... (6)

Section SEFSs

... (4)

Path SESs

... (6)

Line CV

... (10)

Path UASs

... (0)

Line ESs

... (7)

Far End Path CV

... (10)

Line SESs

... (6)

Far End Path ESs

... (7)

Line UASs

... (3)

Far End Path SESs

... (9)

Far End Line CV

... (0)

Far End Path UASs

... (1)

... (N)

 

 

 

>

 

 

 

ESC-prev.menu; !-main menu; &-exit;

 

 

 

 

 

 

 

 

 

 

Figure 5-4. Uplink Statistics Screen, Page 1

Uplink Statistics

 

RIC-155

 

 

 

 

...(P)

... (.)

 

 

Time Elapsed

RCV FCS frames

... (6)

RCV frames

... (6)

XMT frames

... (10)

RCV ABORT frames

... (6)

 

 

XMT ABORT frames

... (10)

>

ESC-prev.menu; !-main menu; &-exit;

 

Figure 5-5. Uplink Statistics Screen, Page 2

 

 

Table 5-1. SDH/SONET Statistics Parameters

 

 

 

 

Display

Description

Range

[15 min]

 

 

 

 

 

Time Elapsed

Number of seconds that have elapsed since the beginning of the current

0–899

 

interval.

 

 

 

 

LOS

Number Loss of Signal errors occurred during the current interval.

0–899

 

 

 

Section CV

Number of Section Coding Violations occurred during the current interval.

0–899

 

Section CVs are not counted during SES_S.

 

 

 

 

Monitoring Performance

5-3

Page 63
Image 63
RAD Data comm RIC-155 operation manual Uplink Statistics Screen, Display Description Range