RIC-155 Installation and Operation Manual Chapter 1 Introduction
Technical Specifications 1-7
Management
V.24/RS-232 ASCII terminal via V.24/RS-232 serial DTE port
Ethernet Telnet, Web browser or RADview via a MNG port
(out-of-band) or DATA port (inband)
Monitoring STM-1/OC-3c Optical input signal
Input signal monitoring based on received B2 error
counting
Frame signal
Alarm indication signal (AIS)
Remote detect indication (RDI)
10/100BaseT Received valid frames
Transmitted valid frames
Alarm Relay Alarm Types Major and minor
Connector DB-9, female
Indicators PWR (green) Power
SPEED (green) LAN speed
LINK/ACT (yellow) Ethernet link integrity and activity
ALM (red) Alarm
SIG (green) Fiber optic or coaxial signal
Power AC Source 10 0 to 240 VAC (±10%), 50 to 60 Hz
DC Source -48 VDC (±10%) or 24 VDC (±10%)
Power Consumption 8.8W
Physical Height 43 mm / 1.7 in
Width 215 mm / 8.4 in
Depth 206 mm / 8.1 in
Weight 1.7 kg / 3.7 lb
Environment Temperature 0–50°C / 32–122°F
Humidity Up to 90%, non–condensing