RIC-155Installation and Operation Manual

Chapter 1 Introduction

 

 

 

Management

V.24/RS-232

ASCII terminal via V.24/RS-232 serial DTE port

 

Ethernet

Telnet, Web browser or RADview via a MNG port

 

 

(out-of-band) or DATA port (inband)

Monitoring

STM-1/OC-3c

Optical input signal

 

 

Input signal monitoring based on received B2 error

 

 

counting

 

 

Frame signal

 

 

Alarm indication signal (AIS)

 

 

Remote detect indication (RDI)

 

10/100BaseT

Received valid frames

 

 

Transmitted valid frames

Alarm Relay

Alarm Types

Major and minor

 

Connector

DB-9, female

Indicators

PWR (green)

Power

 

SPEED (green)

LAN speed

 

LINK/ACT (yellow)

Ethernet link integrity and activity

 

ALM (red)

Alarm

 

SIG (green)

Fiber optic or coaxial signal

Power

AC Source

100 to 240 VAC (±10%), 50 to 60 Hz

 

DC Source

-48 VDC (±10%) or 24 VDC (±10%)

 

Power Consumption

8.8W

Physical

Height

43 mm / 1.7 in

 

Width

215 mm / 8.4 in

 

Depth

206 mm / 8.1 in

 

Weight

1.7 kg / 3.7 lb

Environment

Temperature

0–50°C / 32–122°F

 

Humidity

Up to 90%, non–condensing

Technical Specifications

1-7

Page 21
Image 21
RAD Data comm RIC-155 operation manual Alarm Types Major and minor Connector DB-9, female