Chapter 4 Configuration

RIC-155Installation and Operation Manual

 

 

Resetting RIC-155 to Factory Defaults

You can reset RIC-155 to its default settings. Reseting to the defaults does not affect the master clock setting. In addition, you can reset local RIC-155 without affecting its management parameters (IP address, mask and default gateway).

To reset RIC-155 to the defaults:

1.Follow the path: Configuration >System Configuration > Factory default. Factory Default menu is displayed.

2.From the Factory Default menu, perform one the following steps:

Select All to reset all RIC-155 parameters to the default settings.

Select Without Management to reset all parameters, except for IP address, mask and default gateway values, community names.

RIC-155 displays the following message:

Request to factory default!!! Are you sure? Y/N

3. Type Y to confirm the reset.

RIC-155 performs the requested type of reset.

Resetting RIC-155

You can perform the overall reset of RIC-155.

To reset RIC-155:

1.From the System Configuration menu, select Reset Device. A confirmation message appears.

2.Type Y to confirm the reset.

4-24 Additional Tasks

Page 60
Image 60
RAD Data comm operation manual Resetting RIC-155 to Factory Defaults, To reset RIC-155 to the defaults