Chapter 4 Configuration

RIC-155Installation and Operation Manual

 

 

RIC-155

TELNET Access (Enable)

1.Enable

2.Disable

3.Managers only

Please select item <1 to 3>

ESC-prev.menu; !-main menu; &-exit

Figure 4-7. TELNET Access Menu

To enable or disable management ports:

1.From the Management Access menu, select Physical Ports Access. The Physical Ports Access menu appears (see Figure 4-8).

2.From the Physical Ports Access menu, select None to disable both inband and out-of-band management, MNG only to enable out-of-band management only (via MNG port), or All to enable management via Ethernet management and data ports.

Appendix B illustrates connections between the management port, data port, STM-1/OC-3c port and the CPU within internal bridge.

Note Whenever the Physical Ports Access mode is changed, the POS Port Egress (STM-1/OC-3c) and Tag Stripping (data and management Ethernet ports) are set to their default values as explained in Appendix B.

RIC-155

Physical Ports Access (All)

1.None

2.MNG only

3.All

Please select item <1 to 3>

ESC-prev.menu; !-main menu; &-exit

Figure 4-8. Physical Ports Access Menu

4.2Configuring the RIC-155 for Operation

The RIC-155 management software allows you to perform the following:

Setting source clock

Defining control port parameters

Defining alarm severity and masking alarms

Resetting RIC-155 to the default values

Performing the overall reset of the device.

4-6

Configuring the RIC-155 for Operation

Page 42
Image 42