Using SoftBench Static Analyzer
If Something Goes Wrong
Table
Condition or Message | Explanation |
|
|
Source file filename not | The source file you requested cannot |
found. | be found. Choose "File: Customize |
| File Set…" to add the project (Parent |
| or Subproject) containing the source |
| file which couldn't be found. |
| Alternatively, add the file to the |
| project by choosing "Project: Add |
| File(s) to Project…" and rebuild |
| the project. This may also be an NFS |
| access problem. Your system |
| administrator may need to add access |
| to the remote system that contains the |
| file. |
|
|
Unable to open | SoftBench Static Analyzer cannot |
Static.sadb. | open the Static database. It may be an |
| incompatible version from a previous |
| release of SoftBench. Delete |
| Static.sadb, rebuild the code and try |
| again. |
|
|
Update of Static | Either your Static Analysis Database |
Analysis Database | is from an earlier SoftBench release, |
failed: Scanner exited | in which case you must remove the |
(result==1). | database and regenerate the analysis |
| database files by rebuilding your |
| project (In standalone mode, choose |
| "File: Analyze File Set".); or, you |
| requested "File: Analyze File |
| Set" when running from SoftBench |
| before creating your Static database |
| through a build process. You must |
| first create the database by building |
| your project. |
|
|
Chapter 9 | 279 |