Symptom-to-FRU index 137
217-XXX-003
(F ai le d BI OS Fix ed
Di sk test)
Note: If RA ID is
configured,
the fixed
disk numb er
refers to the
RAID logical
array.
1. Fixed Disk 4
217-XXX-004
(F ai le d BI OS Fix ed
Di sk test)
Note: If RA ID is
configured,
the fixed
disk numb er
refers to the
RAID logical
array.
1. Fixed Disk 5
217-XXX-005
(F ai le d BI OS Fix ed
Di sk test)
Note: If RA ID is
configured,
the fixed
disk numb er
refers to the
RAID logical
array.
1. Fixed Disk 6
264-XXX-0NN
(NN = SCSI ID of
failing Tape Drive)
1. Tape Cartridge, if user
executed the Read/Write
Tape Drive test (XXX = 256)
2. SCSI or power cabl e
connected to the tape drive
with SCSI ID NN
3. Tape drive with SCSI ID NN –
refer to Hel p and Service
Information appendix of tape
drive’s User Guide.
4. I/O Legacy Board or SCSI
Controller – run SCSI
Controller diagnosti c to
determine of SCSI bus is
functioning properly.
264-XXX-999
(Errors on multiple
tape drives, see
error text for more
info)
1. See error messages/text in
the PC Doctor error log for
detailed information on each
individual tape drive error.
Error