Diagnostics 19
Ethernet Link
Sta tu s lig ht
does not
light.
Chec k the following:
Make sure that the hub is turned on.
Check all connections at the Ethernet
c ontroller and the hub.
Check the cable. A crossover cable
is required unless the hub has an
X
designation.
Us e another po rt on the hub.
If the hub d oes not support auto-
negotiation, manually configure the
Etherne t cont ro ller to match the h ub.
If you manually configured the duplex
mode, make sure that you also
m anually configure the speed.
Run diagnostics on the LEDs.
The Ethernet
Transmit/
Receive
Activ i ty lig h t
does not
light.
Chec k the following:
Note: The Ethernet Transmit/Receive
Activity LED illuminates only when
data is sent to or by this Ethernet
controller.
Make sure that you have loaded the
network device drivers.
The network might be id le. Try
sendin g da ta fr o m thi s wor k s tat ion.
Run diagnostics on the LEDs.
The fu nction of this LED c a n be
changed by device driver load
parameters. If necessary, remove
any LED parameter settings when
you load the device drivers.
Data is
incorrect or
sporadic.
Chec k the following:
Make sure that you are using
Cat eg or y 5 cab lin g w he n op eratin g
the server at 10 0 Mbps.
Make su re that the cables do not run
close to noise-inducing sources like
fluorescent lights.

Table 1. Ethernet troubleshooting chart

Ethernet
controller
problem
Suggested Action