30 Net finity 3500 -M20 – T ype 8657 Mod els 21 Y, 2 2Y, 31Y, 32Y ,
pnt0-19 IRQ found for PCnet hardware does not
match space.c (or pnt.conf)!
Explanation: This is a warning message
referring to the interrupt request (IRQ) that the
SunSoft Solaris driver found in the system.
Action: Ignore t his me ssag e if you are sur e
th at thi s i s w hat yo u wa nt to d o. Ot he rwis e, r un
the NETCONFIG program to match the
hardware settings
pnt0-20 add_intr_handler failed! Unknown interr upt
type.
Explanation: The interrupt request (IRQ) that
was specified, or the IR Q that was found,
conflicts with other devices in the server.
Action:
Modify the hardware settings.
Run the NETCONFIG program to search
for another Ethernet controller.
pnt0-21 add_intr_handler failed! Out of range
interrupt number.
Explanation: The interrupt request (IRQ) that
was specified, or the IR Q that was found,
conflicts with other devices in the server.
Action:
Modify the hardware settings.
Run the NETCONFIG program to search
for another Ethernet controller.
pnt0-22 add_intr_handler failed! Out of range IPL.
Explanation: The interrupt request (IRQ) that
was specified, or the IR Q that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings. Run
the NETCONFIG program to search for
another Ethernet controller.
pnt0-23 add_intr_handler failed! Vector already
occupied.
Explanation: The interrupt request (IRQ) that
was specified, or the IR Q that was found,
conflicts with other devices in the server.
Action: Modify the hardware settings.

Table 5. UNIX LLI dri v er messages for the Ethernet

controller