Diagnostics 23
PCNTNW-
NW-086 The driver parameter block is too
small.
Explanation: The d riv er parameter bl ock
is too small.
Action: Restart the server. If the
problem persists, go to “Starting the
diagnostic programs” on page 11 to run
the di agno stic programs.
PCNTNW-
NW-087 The media parameter block is too
small.
Explanation: T he dr iv er me dia
parameter block is too small.
Action: Restart the server. If the
problem persists, go to “Starting the
diagnostic programs” on page 11 to run
the di agno stic programs.
PCNTNW-
NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new
fram e type for the existing controller. Th e
hardware assumptions made in doing so
are incorrect. This error can also occur if
y ou try to specify a mode ( s uch as,
redundan cy) that conflicts with another
specified mode.
Action: Make sure that the hardware
configuration matches the software
settings.
PCNTNW-
NW-126 The group bit in the node address
override was cleared.
Explanation: The IEEE address h as a
group bit that indi cates that an address
belongs to a group of stations. This bit is
us ed only as a destination address; it
cannot be used as a source address. Y ou
tried to enter a source address with this bit
s et. Th e driv er c le are d t he gr oup bi t of the
source address.
Action: None necess ary, m essage is for
infor m a tio n only.
Table 2. Novell NetWare or IntraNetWare ODI driver
messages for the Ethernet controller