22 Net finity 3500 -M20 – T ype 8657 Mod els 21 Y, 2 2Y, 31Y, 32Y ,
PCNTNW-
NW-072 A resource tag is unavailable.
Explanation: The driver tried to allo cate
some resources that were not available.
Action: Add more memory, or free some
memory resources in the server. Then,
restart the server.
PCNTNW-
NW-073 Unable to allocate memory
Explanation: The driver failed to allocate
the memory needed for normal operation.
Action: Add more memory, or free some
memory resources in the server. Then,
restart the server.
PCNTNW-
NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to
initialize a given hardware interrupt. The
attempt was not successful.
Action: Verify that the Ethernet controller
is enab led. If the Ethernet contro ller is
enabled, go to “Starting the diagnostic
programs” on page 11 to run the
diagnostic programs. If you have an
Ethernet adapter installed, make sure that
the ad apter doe s not s hare an IRQ with
any other de v ic e.
PCNTNW-
NW-075 The Multiple Link Interface Driver
(MLID) cannot be registered with the
Link Support Layer (LSL).
Explanation: An error occurred while the
driv er was trying to registe r w ith the LSL.
Action: Check the version of the
NetWare or IntraNetWare Operating
System. Make sure that this driver is
c orrect for the version of NetWare or
IntraNetWare that y ou are using. Restart
the server.
PCNTNW-
NW-079 The Multiple Link Interface Driver
(MLID) did not initialize MSMTx Free
Count.
Explanation: The MSMTx Free Count is
not initialized correctly.
Action: Restart the server. If the problem
persists, go to “S tarting the diagnostic
programs” on page 11 to run the
diagnostic programs.
Table 2. Novell NetWare or IntraNetWare ODI driver
messages for the Ethernet controller