Commands

Table 80. PTR_SETUP Commands (continued)

Command

Sub-Command

Parameter

Description

 

 

 

 

 

 

 

 

CONFIG

DELETE

Cfg

Deletes Configuration number Cfg.

 

 

 

Cfg must be in the range of 1-8.

 

 

 

 

 

UPLOAD

Port;Cfg

This command uploads the

 

 

 

configuration stored in location Cfg

 

 

 

to the port specified by Port. Port

 

 

 

must either be 1284 or SERIAL. Cfg

 

 

 

may be 1-8 or ALL.

 

 

 

 

 

DOWNLOAD

Cfg

This command saves the

 

 

 

configuration data that follows as

 

 

 

configuration Cfg. Cfg must be 1-8

 

 

 

or END.

 

 

 

 

 

RESET

 

Reboots the printer.

 

 

 

 

LP MODE

n/a

Protocol

Protocol must be 0-4. This

 

 

 

command resets the software

 

 

 

protocol, and is selected as follows:

 

 

 

0 - P-Series

 

 

 

1 - P-Series XQ

 

 

 

2 - Serial Matrix

 

 

 

3 - Proprinter III XL

 

 

 

4 - Epson FX-1050

 

 

 

 

FILE_IO

CAPTURE

Filename

Captures all incoming data into a file

(DISK_IO)

 

 

named Filename. Receipt of a

 

 

 

FILE_IO–CAPTURE command

 

 

 

without the Filename parameter will

 

 

 

force the file data to be written to

 

 

 

flash, and will end the file capture.

 

 

 

 

 

DRIVE

Letter

This command is parsed for

 

 

 

backwards compatibility. However,

 

 

 

since the flash file system is a single

 

 

 

device, the drive letter will be

 

 

 

ignored.

 

 

 

 

 

DEL

Filename

The DEL command will mark a file

 

 

 

as deleted. The space the file

 

 

 

occupied will be freed the next time

 

 

 

the printer is powered up.

 

 

 

 

285

Page 285
Image 285
IBM 4400 manual Config Delete, Upload, Download, Reset, LP Mode, Fileio Capture, Diskio, Drive