88
Chapter 4 Configuring the Serial MatrixEmulation with Control Codes
Comment An asterisk character (*) (hex 2A) may be substituted for the
numeric values of
x
,
y
,or
z
. If the asterisk (*) is the value
selected for
x
,t he character set does not change. If * is the value
selected for
y
or
z
, the previouslyselected international
language and/or extended character set for the selected
character set are used.
The character set, international language and extended
character set can also be selected from the printer control panel.
The control code setting overrides the control panel selection.
Except for the asterisk value discussed above, values other than
those shown in the tables results in the control sequence being
terminated.
Characters 80-9F (ControlCodes)
ASCII Code ESC 7
Hex Code 1B 37
Dec Code 27 55
Purpose Selects the character set wherein hex codes 80 through 9F are
control codes. Also includes hex codes 03 through 06 and 15 in
the Serial Matrix printer protocol. Cancels Character Set Select
activatedby ESC 6 or ESC u.
Comment This feature is also selectable from the control panel (see the
“Alternate Set 80-9F” parameter in the configuration chapter of
your
Users Guide
).