InitializeParameters
135
n4

and

n5
Parameter bytes
n4
and
n5
allow you to define several configuration
parameters that will override conflicting factory default and memory-based
configuration values when the printer is reinitialized. Possible values for
n4
and
n5
are listed in Table 28 and Table 29, respectively.
NOTE: Ina ddition to the formatting from bytes
n4
and
n5
,this command sets
the current line as top-of-form. It also clears vertical tabs and sets the
horizontal tabs at every eight columns, starting at column 9.
Table 2 8.
n4
Values
n4
Bit Function OFF (0) ON (1)
7 Process this byte Process Ignore
6 Reserved Reserved Reserved
5 n/a n/a n/a
4 Line Feed =LF LF +CR
(add CR with each LF)
3 Carriage Return =CR CR+LF
(add LF with each CR)
2 Set forms length 11 inches 12inches
1 Slashed Zero Disable Enable
0 Character set 1(A) 2(B)
Table 2 9.
n5
Values
n5
Bit Function OFF (0) ON (1)
7 Process this byte Process Ignore
6 Code page 437 850
5 Unidirectional
Printing Bidirectional Unidirectional
4 12 cpi compressed
to 20 20 12
3 n/a n/a n/a
2 Form feed at TOF Enable Ignore
1 Print Width 13.2 inches 8i nches
0 Sheet feeder n/a n/a